![31833](http://www.hccontrols.com/assets/images/cecvp/cables/cable-31833.png) |
31833 |
Teflon jacket, copper shield, 2 conductor twisted, 24 Awg, 0.128"" OD, 400°F (204°C) - Electric Cable |
|
![81293](http://www.hccontrols.com/assets/images/cecvp/cables/cable-81293.png) |
81293 |
Teflon jacket, copper shield, 4 conductor twisted, 24 Awg, 0.150"" OD, 300°F (149°C) |
Used on 4-202 accelerometers |
![157475](http://www.hccontrols.com/assets/images/cecvp/cables/cable-157475.png) |
157475 |
Neoprene jacket, steel braid shield , 2 conductor, 20 Awg, 0.285"" OD, 200°F (93°C) |
Used on 49657 assemblies |
![167811](http://www.hccontrols.com/assets/images/cecvp/cables/cable-167811.png) |
167811 |
#302 braid outer shield, 2 conductor, 20 Awg, 0.238"" OD, 700°F (371°C) |
Used on 169500 assemblies |
![168567](http://www.hccontrols.com/assets/images/cecvp/cables/cable-168567.png) |
168567 |
Teflon jacket, annealed copper shield, 2 conductor twisted, 20 Awg, 0.163"" OD, 392°F (200°C) |
Used on 82406 assemblies |
![174123](http://www.hccontrols.com/assets/images/cecvp/cables/cable-174123.png) |
174123 |
Teflon jacket, nickel plated copper shield braid, 2 conductor, 18 Awg, 0.275" OD, 500°F (260°C) |
Used on 173970 assemblies |
![550502](http://www.hccontrols.com/assets/images/cecvp/cables/cable-550502.jpg) |
550502 |
Glass braid, heat resistant outer jacket, double steel braid shielded, 2 conductor, 20 Awg, 0.342" OD, 700°F (371°C) |
|
![614899](http://www.hccontrols.com/assets/images/cecvp/cables/cable-614899.png) |
614899 |
Double steel braid shielded, 2 conductor, 20 Awg, 0.323"" OD, 500°F (260°C) |
Used on 614748 assemblies |
![616351](http://www.hccontrols.com/assets/images/cecvp/cables/cable-616351.png) |
616351 |
Low noise, carbon shielded, 2 conductor, 20 Awg, 0.225"" OD, 500°F (260°C) |
Used on differential charge cable assemblies |
![618335](http://www.hccontrols.com/assets/images/cecvp/cables/cable-618335.png) |
618335 |
Coaxial Cable |
|
![618376](http://www.hccontrols.com/assets/images/cecvp/cables/cable-618376.png) |
618376 |
#302 braid outer shield, 2 conductor, 20 Awg, 0.270"" OD, 900°F (482°C) |
|
![618569](http://www.hccontrols.com/assets/images/cecvp/cables/cable-618569.png) |
618569 |
Low Noise Coaxial Cable |
|
![700785-90-0001](http://www.hccontrols.com/assets/images/cecvp/cables/cable-700785-90-0001.png) |
700785-90-0001 |
18 Awg., 2 conductor Nickel plated copper. Braided shield w/ black Teflon outer |
Used on 780045 assemblies |
![70104-0222](http://www.hccontrols.com/assets/images/cecvp/cables/cable-70104-0222.png) |
70104-0222 |
Vinyl jacket, tinned copper shield, 2 conductor twisted, 22 awg., 0.158"" OD, 221°F (105°C) |
|
![70104-0322](http://www.hccontrols.com/assets/images/cecvp/cables/cable-70104-0322.png) |
70104-0322 |
Vinyl jacket, tinned copper shield, 3 conductor twisted, 22 awg., 0.168"" OD, 221°F (105°C) |
|